Lotus Logo
UV-C Disinfection Technology

Industrial UV-C Disinfection Systems

Chemical-free water disinfection using germicidal ultraviolet light at 254nm wavelength. Instant pathogen inactivation for industrial, municipal, and commercial applications manufactured at our world-class facility in Chennai, India.

The Science of UV Disinfection

Germicidal UV-C at 254nm Wavelength

UV-C light at 254 nanometers is the optimal germicidal wavelength. At this wavelength, UV photons are absorbed by the DNA and RNA of microorganisms, causing thymine dimer formation that prevents replication.

This physical disinfection process is instantaneous, chemical-free, and leaves no residual by-products — making it ideal for industrial water treatment, food processing, and environmental applications.

254nm Wavelength
DNA/RNA Disruption
Chemical-Free
Instant Action

UV-C Light

254nm Germicidal Wavelength

99.99% Pathogen Reduction

Made in India

Chennai Manufacturing

Why Choose UV-C Disinfection?

Advanced disinfection technology with proven advantages over chemical treatment

Chemical-Free Disinfection

Eliminates pathogens without adding chemicals, producing no harmful by-products or residual pollutants

Instant Pathogen Inactivation

UV-C light damages DNA/RNA instantly, preventing microorganisms from reproducing

Broad Spectrum Effectiveness

Effective against bacteria, viruses, and chlorine-resistant parasites like Cryptosporidium & Giardia

No Water Property Alteration

Maintains pH, temperature, taste, and odour - no changes to water chemistry

Environmentally Sustainable

Low carbon footprint with no disinfection by-products (DBPs) - ideal for water reuse applications

Low Operational Costs

Minimal maintenance requirements with long lamp life up to 12,000+ hours

Low-Pressure vs Medium-Pressure UV Systems

Lotus Ozone offers both LP and MP UV systems to match your specific application requirements

Parameter
Low-Pressure (LP)
Medium-Pressure (MP)
Wavelength Output
254 nm (monochromatic)
200-600 nm (polychromatic)
Energy Efficiency
Up to 40% UV-C conversion
~10-15% UV-C conversion
Lamp Life
10,000-16,000 hours
5,000-10,000 hours
System Footprint
Larger (more lamps needed)
Compact (fewer lamps)
Best For
Variable/intermittent flows
Constant high-volume flows
Heat Generation
Minimal
Higher (may need cooling)

Choose Low-Pressure When:

  • Energy efficiency is priority
  • Variable or intermittent flow conditions
  • Lower operating costs required

Choose Medium-Pressure When:

  • Compact footprint is essential
  • Constant high-volume flow operation
  • Broader spectrum pathogen control needed
System Architecture

UV System Components

Industrial-grade components engineered for reliability and performance

UV-C Lamps

Low-pressure or medium-pressure mercury lamps generating germicidal 254nm wavelength

8W to 50,000W range

Quartz Sleeves

High-purity quartz tubes protecting lamps while allowing maximum UV transmission

>90% UV transmittance

Reactor Chamber

304/316L stainless steel chambers, polished and passivated for optimal reflection

10-150 PSI rated

UV Sensors

Real-time intensity monitoring with calibrated sensors for dose verification

mW/cm² measurement

Control Panel

Electronic ballasts with lamp status, alarms, and operating hour counters

80-265V universal input

Wiper System

Automatic mechanical or chemical cleaning systems for quartz sleeve maintenance

Optional for high-turbidity
Industrial Applications

UV-C Across Industries

Versatile disinfection solutions for diverse industrial sectors

Industrial Wastewater

Final disinfection step for effluent treatment and water recycling

Food & Beverage

Disinfection of process water, ingredient water, and packaging

Pharmaceutical

Ultra-pure water treatment for manufacturing and cleaning

Aquaculture

Pathogen control in recirculating aquaculture systems (RAS)

Municipal Water

Drinking water disinfection and wastewater treatment plants

Surface Disinfection

Conveyor belts, packaging materials, and food contact surfaces

Complete UV Solutions for All Treatment Requirements

Water Treatment
Waste Water
Effluent Treatment
Food Processing
Pharmaceutical
Aquaculture

UV Dose & Performance Standards

Our systems are designed to meet international disinfection standards

NSF/ANSI 55 Class A

≥40 mJ/cm²

Contaminated water treatment

NSF/ANSI 55 Class B

≥16 mJ/cm²

Supplemental disinfection

3-Log Reduction

~12 mJ/cm²

Cryptosporidium inactivation

4-Log Reduction

~22 mJ/cm²

Virus inactivation

Important: UV Transmittance (UVT)

UV system performance depends on water's UV Transmittance (UVT). For optimal disinfection, UVT should be ≥75% at 254nm. Lower UVT requires higher-powered systems or pre-treatment. Our engineers will assess your water quality to specify the right system.

Quality Commitment

Engineered for Reliability

Our UV systems are manufactured to the highest quality standards at our world-class facility in Chennai, India. Every system undergoes rigorous testing and validation before deployment.

We follow Total Quality Management (TQM) principles and the Kaizen philosophy of continuous improvement across all manufacturing processes.

Quality Standards

304/316L SS Chambers
High-Purity Quartz
Calibrated Sensors
Validated Performance

TQM & Kaizen

Continuous Improvement Philosophy

Frequently Asked Questions

Common Questions About UV Disinfection

Straight answers on what UV-C does — and what it doesn't.

Ready to Implement UV-C Disinfection?

Our engineers will help you select the right UV system for your application